Quantcast
Channel: All Centrify Express posts
Viewing all articles
Browse latest Browse all 1833

Re: Centrify does not start after AIX Update to TL5

$
0
0

Thanks for opening the issue internally.

Here is an update.

We opted to uninstall (unistall.sh and removed all related subsystems entries) and re-install Centrify Express and Samba Integration then we saw your message.Hopefully, what has happened can help your folks help us.

The entire process was done as root. No sudo. No su. Straight root.

During the reinstall it hung in the same place as before.

Here is the result:

WARNING: Centrify adcheck exited with warning(s).
Unzipping ./centrifydc-5.4.2-aix7.1-ppc-bff.gz to /var/centrify/install-tmp* ...
Unzipping ./centrifydc-openssl-5.4.2-aix7.1-ppc-bff.gz to /var/centrify/install-tmp* ...
Unzipping ./centrifydc-openldap-5.4.2-aix7.1-ppc-bff.gz to /var/centrify/install-tmp* ...
Unzipping ./centrifydc-curl-5.4.2-aix7.1-ppc-bff.gz to /var/centrify/install-tmp* ...
Installing all from spool dir ...
Joining the Active Directory domain pg.local ...
Using domain controller: dc3.pg.local writable=true
Join to domain:pg.local, zone:Auto Zone successful

Centrify DirectControl started.

The warning came from DOMNAME and using.local as part of the FDQN.

 

Here are the errpt entries:

They begin with

 

---------------------------------------------------------------------------
LABEL:          CORE_DUMP
IDENTIFIER:     A924A5FC

Date/Time:       Thu Dec 14 12:02:47 CST 2017
Sequence Number: 869
Node Id:         psa
Class:           S
Type:            PERM
WPAR:            Global
Resource Name:   SYSPROC

Description
SOFTWARE PROGRAM ABNORMALLY TERMINATED

Probable Causes
SOFTWARE PROGRAM

User Causes
USER GENERATED SIGNAL

        Recommended Actions
        CORRECT THEN RETRY

Failure Causes
SOFTWARE PROGRAM

        Recommended Actions
        RERUN THE APPLICATION PROGRAM
        IF PROBLEM PERSISTS THEN DO THE FOLLOWING
        CONTACT APPROPRIATE SERVICE REPRESENTATIVE

Detail Data
SIGNAL NUMBER
           6
USER'S PROCESS ID:
               2490692
FILE SYSTEM SERIAL NUMBER
           4
INODE NUMBER
                 65536
CORE FILE NAME
/var/centrifydc/core
PROGRAM NAME
adclient
STACK EXECUTION DISABLED
           0
COME FROM ADDRESS REGISTER
thread_se 1FC

PROCESSOR ID
  hw_fru_id: N/A
  hw_cpu_id: N/A

ADDITIONAL INFORMATION
_set_canc 48
??
pthread_s 64
pthread_s 14
_ZN4cims4 E0
_ZN4cims4 20
_ZN4cims1 24
_ZN4cims8 544
_ZN4cimsL 148
_ZN4cims6 1C4
_ZN4cims9 16AC
main 4D70
__start 74

Symptom Data
REPORTABLE
1
INTERNAL ERROR
0
SYMPTOM CODE
PCSS/SPI2 FLDS/adclient SIG/6 FLDS/_set_canc VALU/48

Followed by..

 

---------------------------------------------------------------------------
LABEL:          SRC_SVKO
IDENTIFIER:     BC3BE5A3

Date/Time:       Thu Dec 14 12:20:08 CST 2017
Sequence Number: 872
Node Id:         psa
Class:           S
Type:            PERM
WPAR:            Global
Resource Name:   SRC

Description
SOFTWARE PROGRAM ERROR

Probable Causes
APPLICATION PROGRAM

Failure Causes
SOFTWARE PROGRAM

        Recommended Actions
        MANUALLY RESTART SUBSYSTEM IF NEEDED

Detail Data
SYMPTOM CODE
      393222
SOFTWARE ERROR CODE
       -9017
ERROR CODE
           0
DETECTING MODULE
'srchevn.c'@line:'376'
FAILING MODULE
centrifydc
---------------------------------------------------------------------------
LABEL:          SRC_SVKO
IDENTIFIER:     BC3BE5A3

Date/Time:       Thu Dec 14 12:11:18 CST 2017
Sequence Number: 871
Node Id:         psa
Class:           S
Type:            PERM
WPAR:            Global
Resource Name:   SRC

Description
SOFTWARE PROGRAM ERROR

Probable Causes
APPLICATION PROGRAM

Failure Causes
SOFTWARE PROGRAM

        Recommended Actions
        MANUALLY RESTART SUBSYSTEM IF NEEDED

Detail Data
SYMPTOM CODE
      393222
SOFTWARE ERROR CODE
       -9017
ERROR CODE
           0
DETECTING MODULE
'srchevn.c'@line:'376'
FAILING MODULE
centrifydc
---------------------------------------------------------------------------
LABEL:          SRC_SVKO
IDENTIFIER:     BC3BE5A3

Date/Time:       Thu Dec 14 12:02:47 CST 2017
Sequence Number: 870
Node Id:         psa
Class:           S
Type:            PERM
WPAR:            Global
Resource Name:   SRC

Description
SOFTWARE PROGRAM ERROR

Probable Causes
APPLICATION PROGRAM

Failure Causes
SOFTWARE PROGRAM

        Recommended Actions
        MANUALLY RESTART SUBSYSTEM IF NEEDED

Detail Data
SYMPTOM CODE
      393350
SOFTWARE ERROR CODE
       -9017
ERROR CODE
           0
DETECTING MODULE
'srchevn.c'@line:'376'
FAILING MODULE
centrifydc

Looks like the program is trying to recover/restart but just can't.

 

 